iP5A

iP5A

 

 

 

 

iP5A

 

 Fan & Pump specialized VFD Starvert iP5A series adopt various functions as standard for operation of Fan and Pump.

Manual Catalog Technical Data Certification CAD Data Software

 

Dual PID

When additional PID control or Cascade PID control is required, Dual PID provides users various uses of the system with only iP5A.

Multi Motor Control

The built-in algebra control function enables an inverter to control many motors without a controller so that user can take advantage of energy-saving and cost-down.

Sleep and Wake-Up

The built-in energy saving function makes inverter stop automatically when the capacity is very low.

Pre Heater

The pre heater function is built-in to prevent motor damage and inverter break-down caused from humidity.

Flying Start

When the inverter drives many ventilators or when the fan in a big load system turns due to a natural convection, iP5A operates the motor by searching the motor speed automatically.

Auto energy saving

iP5A provides the auto energy saving function by the optimal flux control which minimizes an energy loss caused by a change of the load.

Improved Management from Instant Power-off and Power Dip Generation

During the power Dip or instant power-off, which is generated by lightening, ground fault and power-failure, loads still keep the mechanical energy and this energy flows back to inverter by regeneration. The power-failure guarantee time is extended by using this electrical character of inverter.

Constant and Stable Performancel (24 hours 365 days)

Regardless of outside alteration such as input voltage variation by load change or weather effect, iP5A can handle moter and load with best performance.

Safety Stop

When unexpected power-failure blocks power supply, inverter stops motor by using inertia energy of load that prevents unexpected second accident (Parameter setting is required).

 

SV ㅁㅁㅁ iP5A - 2 008 015 022 037 055 075 110
Motor Rating [HP] 1 2 3 5 7.5 10 15
15[kW] 0.75 1.5 2.2 3.7 5.5 7.5 11
Output ratings Capacity[kVA] 2) 1.9 3 4.6 6.1 9.1 12.2 17.5
Rated current[A] 5 8 12 16 24 32 46
Output frequency 0.01 ~ 120 [Hz]
Output voltage(V) 200 ~ 230V
Input ratings Voltage[V] 3 Phase 200~230 V (-15% ~ +10%)
Frequency 50 ~ 60 [Hz] (± 5%)
Weight (kg) 4.1 4.2 4.2 4.9 4.9 6 6
SV ㅁㅁㅁ iP5A - 2 150 185 220 300
Motor Rating [HP] 20 25 30 40
[kW] 15 18.5 22 30
Output ratings Capacity[kVA] 2) 22.9 28.3 33.5 43.8
Rated current[A] 60 74 88 115
Output frequency 0.01 ~ 120 [Hz]
Output voltage(V) 200 ~ 230V
Input ratings Voltage[V] 3 Phase 200~230 V (-15% ~ +10%)
Frequency 50 ~ 60 [Hz] (± 5%)
Weight (kg) 13 13.5 20 20
400V Class
SV ㅁㅁㅁ iP5A - 4 008 015 022 037 055 075 110
Motor Rating [HP] 1 2 3 5 7.5 10 15
[kW] 0.75 1.5 2.2 3.7 5.5 7.5 11
Output ratings Capacity [kVA] 2) 2 3 4.8 6.4 9.6 12.7 19.1
Rated current[A] 2.5 4 6 8 12 16 24
Output frequency 0.01 ~ 120 [Hz]
Output voltage(V) 380 ~ 480V
Input ratings Voltage[V] 3 Phase 380~480 V (-15% ~ +10%)
Frequency 50 ~ 60 [Hz] (± 5%)
Weight (kg) 4.1 4.2 4.2 4.9 4.9 6 6

 

SV ㅁㅁㅁ iP5A - 4 150 185 220 300 370 450 550
Motor Rating [HP] 20 25 30 40 50 60 75
[kW] 15 18.5 22 30 37 45 55
Output ratings Capacity [kVA] 2) 23.9 31.1 35.9 48.6 59.8 72.5 87.6
Rated current[A] 30 45 45 61 75 91 110
Output frequency 0.01 ~ 120 [Hz]
Output voltage(V) 380 ~ 480V
Input ratings Voltage[V] 3 Phase 380~480 V (-15% ~ +10%)
Frequency 50 ~ 60 [Hz] (± 5%)
Weight (kg) 12.5 13 20 20 27 27 29

 

SV ㅁㅁㅁ iP5A - 4 750 900 1100 1320 1600 2200 2800
Motor Rating [HP] 100 125 150 200 250 300 350
[kW] 75 90 110 132 160 220 280
Output ratings Capacity [kVA] 2) 121.1 145.8 178 210 259 344 436
Rated current[A] 152 183 223 264 325 432 547
Output frequency 0.01 ~ 120 [Hz]
Output voltage(V) 380 ~ 480V
Input ratings Voltage[V] 3 Phase 380~480 V (-15% ~ +10%)
Frequency 50 ~ 60 [Hz] (± 5%)
Weight (kg) 42 43 101 101 114 200 200
SV ㅁㅁㅁㅁ iP5A - 4 3150 3750 4500
Motor Rating [HP] 400 500 600
[kW] 315 375 450
Output ratings Capacity [kVA] 2) 488 582 699
Rated current[A] 613 731 877
Output frequency 0.01 ~ 120 [Hz]
Output voltage(V) 380 ~ 480V
Input ratings Voltage[V] 3 Phase 380~480 V (-15% ~ +10%)
Frequency 50 ~ 60 [Hz] (± 5%)
Weight (kg) 243 380 380
600V Class
SV ㅁㅁㅁ iP5A - 6 055 075 110 150 185 220 300
Motor Rating [HP] 7.5 10 15 20 25 30 40
[kW] 5.5 7.5 11 15 18.5 22 30
Output ratings Capacity [kVA] 2) 9.6 12.7 19.1 23.9 31.1 35.9 48.6
Rated current[A] 9 12 17 23 27 34 43
Output frequency 0.01 ~ 120 [Hz]
Output voltage(V) 525 ~ 600V
Input ratings Voltage[V] 3 Phase 525~600 V (-15% ~ +10%)
Frequency 50 ~ 60 [Hz] (± 5%)
Weight (kg) 6.5 7 7 11.7 11.7 18.9 18.9
SV ㅁㅁㅁ iP5A - 6 370 450 550 750 900 1100
Motor Rating [HP] 50 60 75 100 125 150
[kW] 37 45 55 75 90 110
Output ratings Capacity [kVA] 2) 59.8 72.5 87.6 121.1 145.8 178
Rated current[A] 55 64 80 104 128 150
Output frequency 0.01 ~ 120 [Hz]
Output voltage(V) 525 ~ 600V
Input ratings Voltage[V] 3 Phase 525~600 V (-15% ~ +10%)
Frequency 50 ~ 60 [Hz] (± 5%)
Weight (kg) 32 32 32 46 46 101

 