Warning: file_put_contents(): Only 0 of 5394 bytes written, possibly out of free disk space in /home/wwwbarghoenergy/public_html/libraries/joomla/filesystem/file.php on line 440








 High torque micro VFD Inverter featuring on strong torque performance and accurate control for general use iS7 generates more powerful performance in terms of V/F control, V/F PG, slip compensation, sensorless vector control, PMSM (Permanent Magnetic Synchronous Motor) and focuses on user-friendly interface and environment-friendly features including wide graphic LCD keypad, user & macro group support, electro-thermal functions for motor protection, protection for input/output phase Open.

Manual Catalog Technical Data Certification CAD Data Software


  • Sensorless vector control The iC5 adopts sensorless vector control algorithm, and it improves not only the torque control characteristics, but the speed controlability in an uncertain condition caused by the load variation as well.
  • Auto Tuning The auto tuning algorithm in the iC5 sets the motor factors automatically that brings the traditional commissioning difficulties mainly in low speed by the load variation and the low torque generation to a settlement.
  • Highly efficient DSP chip The iC5 adopts highly efficient DSP(Digital Signal Processing) chip to improve processing speed, flexibility, stability and etc.
  • PNP, NPN Dual Control Signal The iC5 provides PNP and NPN signals for outside controllers. It works with 24Vdc regardless of the type of PLC or control signals.
  • Communication interface, Modbus-RTU The iC5 provides the most popular communication interface, ModBus-RTU for remote control by PLC or other devices.
  • PID Control PID process control is used in iC5 to make speed corrections quickly with a minimal amount of overshoot and oscillation for the control of flow, temperature, pressure and etc.




Type SV004 iC5-1 SV008 iC5-1 SV015 iC5-1 SV022 iC5-1
200V Class Motor Rating [HP] 0.5 1 2 3
[kW] 0.4 0.75 1.5 2.2
Output ratings Capacity[kVA] 0.95 0.95 3.0 4.5
FLA[A] 2.5 0.95 3.0 4.5
Output frequency 0 ~ 400Hz
Output voltage 3 Phasde200~230V
Input ratings Voltage Single phase 200 ~ 230 V (±10%)
FLA[A] 5.5 9.2 16 21.6
Frequency 50 ~ 60 Hz (± 5%)
Control Control method V/F control, Sersorless vector control
Frequency setting resolution Digital reference: 0.01Hz Analog referency: 0.06Hz/60Hz
Frequency setting resolution Digital reference: 0.01Hz Analog referency: 0.06Hz/60Hz
V/F ratio Linear, Square pattern, User V/F
Overload capacity 1 min at 150%, 30 sec at 200% (with inverse characteristic)
Torque boost Manual torque boost (0~15 adjustable), auto torque boost
Input signal Operation method Keypad / Terminal / Communications
Frequency setting Analog: 0~10V / 4~20mA, Digital: Keypad, Communication: RS485 (Option)
Start signal Forward, Reverse
Multi-step accel/decal time 0.1~6000 sec. Max. 8 types available by multi-function terminal, Selectable accel/decel patterns : Linear, U and S
Emergency stop Interrupting the output of the drive.
Jog Jog operation
Fault reset Reset the fault when protective function is active
Output signal Operation status & fault output Frequency detection, Overload alarm, Stalling, Overvoltage, Undervoltage, Drive overheating, Run, Stop, Constant speed, Speed searching, Fault output ( Relay and Open collector output )
Indicator Choose one from output frequency, current, voltage and DC voltage.(Output voltage : 0~10V )
Operation function DC braking, Frequency limit, Frequency jump, Second function, Slip compensation, Reversing prevention, Auto restart, PID control
Protection functions Drive trip Overvoltage, Undervoltage, Overcurrent, Drive overtemperature, Motor overtemperature, I/O phase loss, I/O mis-wiring, Overload , External device fault 1.2, Loss of speed command, Hardware fault, Communication error, CPU error
Drive alarm Stall prevention, Overload alarm
Momentary power loss Less than 15 msec: keeping operation More than 15 msec: auto restart available
Display Keypad Operation information Output frequency, current and voltage, Set frequency value, Operation speed, DC voltage
Trip information Display the trip cause when the protection function activates. Recent 5 faults records stored
Environment Ambient temperature -10 ~ 40℃
Storage temperature -20 ~ 65℃
Humidity 90 %RH max (No condensing)
Atmosphere No corrosive gas, flammable gas, oil mist or dust
Pressure 70 ~ 106k Pa

More in this category: iV5L »

Abute Us

Contact Us

  • Central Shop : No.235,First Floor,Alboorz 20 Shoping Center,Lale zar no,Tehran,Iran
  • Phone : +98 21 6634 47 14 - 6634 46 96

                +98 21 6634 10 91 - 6634 10 92

  • Fax: +98 21 6634 10 90
  • Cell Phone: (M.Mahmudi) +98 912 524 77 38

Our Location